HRW RW Series 33kV~35kV Drop-out Fuse Outdoor High-Voltage Protection Device
Product Overview
The HRW and RW series 33kV~35kV drop-out fuses produced and sold by Gaosuo Electric Co., Ltd. are held in the closed position by the tension of the fuse element during normal operation. When a fault occurs in the system, the fault current causes the fuse element to melt rapidly, creating an arc. The arc-extinguishing tube, subjected to the heat of the arc, decomposes a large amount of gas, creating high pressure inside the tube, which is blown longitudinally, rapidly elongating and extinguishing the arc. After the fuse element melts, the lower moving contact loses tension and flips downward, and the locking mechanism releases the fuse tube, which then drops, forming a clear disconnection position. When it is necessary to break the load, an insulating pole is used to pull the moving contact. At this point, the main moving and fixed contacts are still in contact. As the insulating pole continues to pull the contact, the auxiliary contacts also separate, creating an arc between them. The arc is elongated in the narrow slot of the arc chute, and the arc chute generates gas, extinguishing the arc at current zero.
33kV~35kV series drop-out fuses are outdoor high-voltage protection devices in power transmission and distribution systems. They are installed on the high-voltage side of distribution transformers or on branch trunk lines of distribution lines, serving as short-circuit and overload protection for transformers and lines, as well as for making and breaking load currents. These HRW drop-out fuses and RW drop-out fuses have notable features: 1. After installing a high-voltage fuse element, they protect the circuit and interrupt fault currents; 2. They use composite (silicone rubber) material insulators, providing excellent insulation performance; 3. After the fuse element melts, the fuse tube drops automatically, forming a clear isolation distance, which is very safe.
Composite drop-out fuses consist of a composite (silicone rubber) insulating support and a fuse tube. The fixed contacts are installed at both ends of the insulating support, and the moving contacts are installed at both ends of the fuse tube. The fuse tube is composed of an inner arc-extinguishing tube and an outer phenolic paper tube or epoxy fiberglass tube. Load-break drop-out fuses are enhanced with resilient auxiliary contacts and an arc chute for making and breaking load currents, serving as critical outdoor high-voltage protection devices.
Main Technical Parameters
◆ 33KV-36KV (Type I)
| Parameter |
Unit |
| Rated Voltage |
kV |
| Rated Current |
A |
| Breaking Current |
A |
| Impulse Voltage (BIL) |
kV |
| Power Frequency Withstand Voltage |
kV |
| Creepage Distance |
MM |
| Weight |
KG |
| Overall Dimensions |
CM |
| Rated Voltage(kv) |
Rated Current(A) |
Breaking Current(A) |
Impulse Voltage(BIL) |
Power Frequency Withstand Voltage |
Creepage Distance(MM) |
Weight(KG) |
Overall Dimensions(CM) |
| 36 |
100 |
10000 |
170 |
70 |
720 |
7 |
61×34×11.5 |
| 36 |
200 |
12000 |
170 |
70 |
720 |
7 |
61×34×11.5 |
◆ 33KV-36KV (Type II)
| Rated Voltage(kv) |
Rated Current(A) |
Breaking Current(A) |
Impulse Voltage(BIL) |
Power Frequency Withstand Voltage |
Creepage Distance(MM) |
Weight(KG) |
Overall Dimensions(CM) |
| 33 |
100 |
10000 |
170 |
70 |
720 |
8 |
64×35×18 |
| 33 |
200 |
12500 |
170 |
70 |
720 |
8 |
64×35×18 |
◆ 15KV-27KV (With Arc Chute Type)
| Rated Voltage(kv) |
Rated Current(A) |
Breaking Current(A) |
Impulse Voltage(BIL) |
Power Frequency Withstand Voltage |
Creepage Distance(MM) |
Weight(KG) |
Overall Dimensions(CM) |
| 15 |
100 |
8000 |
125 |
45 |
320 |
8 |
58×40×15 |
| 15 |
200 |
12500 |
125 |
45 |
320 |
8 |
58×40×15 |
◆ 15KV-27KV (Standard Type)
| Rated Voltage(kv) |
Rated Current(A) |
Breaking Current(A) |
Impulse Voltage(BIL) |
Power Frequency Withstand Voltage |
Creepage Distance(MM) |
Weight(KG) |
Overall Dimensions(CM) |
| 15 |
100 |
8000 |
125 |
45 |
320 |
6.5 |
50×36×12.5 |
| 15 |
200 |
12500 |
125 |
45 |
320 |
6.5 |
50×36×12.5 |