Shanghai Gaosuo Electrical Co., Ltd.
product

Drop-out Fuse

Reliable Power, Reliable Business

Product Title

15kV Series Drop-out Fuse RW12-12KV/200A

The RW12-12KV/200A is a 15kV outdoor high-voltage drop-out fuse used for distribution transformers and line branch trunk lines, providing short-circuit and overload protection. Its core advantages include composite silicone rubber insulation, automatic dropout break, and high breaking capacity, complying with relevant high-voltage apparatus standards.
15kV Series Drop-out Fuse RW12-12KV/200A

Product Details

Product Details

15kV Series Drop-out Fuse RW12-12KV/200A

RW12-12KV/200A 15kV Drop-out Fuse Outdoor High-Voltage Protection Device

Product Overview

The RW12-12KV/200A 15kV drop-out fuse is an outdoor AC high-voltage protection device with dimensions of 50*36*12.5cm, weight approximately 8kg, creepage distance 320mm, power frequency withstand voltage 45kV, and impulse withstand voltage 125kV. This 15kV drop-out fuse has a rated voltage of 15kV, rated current options of 100A or 200A, and a breaking current as high as 8000A to 12500A, specifically designed for power transmission and distribution systems.

Drop-out fuses are typically installed on the high-voltage side of distribution transformers or on branch trunk lines of distribution lines, serving as short-circuit and overload protection for transformers and lines, as well as for making and breaking load currents. The product features are notable: 1. After installing a high-voltage fuse element, it reliably protects the circuit and interrupts fault currents; 2. Uses composite (silicone rubber) material insulators, providing superior insulation performance and strong anti-pollution flashover capability; 3. After the fuse element melts, the fuse tube drops automatically, forming a clear isolation break, ensuring operational safety.

The HRW and RW series 15kV drop-out fuses produced by FAURE/Gaosuo Electric are held closed by the tension of the fuse element during normal operation. When a fault occurs, the fault current causes the fuse element to melt rapidly and create an arc. The arc-extinguishing tube is heated to decompose a large amount of gas, creating a longitudinal blowing effect that rapidly extinguishes the arc. Subsequently, the fuse tube drops automatically under the action of the mechanical release mechanism, forming a clearly visible disconnection point. As a load-break drop-out fuse, it can also be operated with an insulating pole to make and break rated load currents.

Composite drop-out fuses consist of a silicone rubber composite insulating support and a fuse tube. The silicone rubber material, with its excellent hydrophobicity, UV resistance, and anti-aging properties, significantly enhances the operational safety and service life of models like the RW12-12KV/200A in harsh outdoor environments. This composite insulation design has been fully validated in high-voltage apparatus such as zinc oxide arresters and fully meets outdoor usage requirements.

Main Technical Parameters

◆ 12KV-15KV

Parameter Unit Value
Model - YK-4
Rated Voltage kV 12
Rated Current A 100 / 200
Breaking Current A 8000 / 12500
Impulse Voltage (BIL) kV 125
Power Frequency Withstand Voltage kV 45
Creepage Distance MM 320
Weight KG 7.5
Overall Dimensions CM 50×36×12.5

◆ 15KV-27KV

Parameter Unit Value
Model - HYK-4
Rated Voltage kV 15
Rated Current A 100 / 200
Breaking Current A 8000 / 12500
Impulse Voltage (BIL) kV 125
Power Frequency Withstand Voltage kV 45
Creepage Distance MM 320
Weight KG 8
Overall Dimensions CM 58×40×15

◆ 15KV-27KV (Composite Insulated Type)

Parameter Unit Value
Model - FSC(X)
Rated Voltage kV 12
Rated Current A 100 / 200
Breaking Current A 8000 / 12500
Impulse Voltage (BIL) kV 125
Power Frequency Withstand Voltage kV 45
Creepage Distance MM 320
Weight KG 6.5
Overall Dimensions CM 40×36×11.5

◆ 12KV RW12-12KV/200A

Parameter Unit Value
Model - RW12-12KV/100A
Rated Voltage kV 12
Rated Current A 100
Breaking Current A 6300
Impulse Voltage (BIL) kV 110
Power Frequency Withstand Voltage kV 42
Creepage Distance MM 230
Parameter Unit Value
Model - RW12-12KV/200A
Rated Voltage kV 12
Rated Current A 200
Breaking Current A 8000
Impulse Voltage (BIL) kV 110
Power Frequency Withstand Voltage kV 42
Creepage Distance MM 230

RW12-12KV/200A_15kV Drop-out Fuse_Outdoor High-Voltage Protection